Renesas M3062PT3-RPD-E Network Card User Manual


 
M3062PT3-RPD-E User’s Manual 2. Setup
REJ10J0040-0600 Rev.6.00 July 01, 2006 Page 38 of 104
2.8.8 Connecting to a 128-pin 0.5mm Pitch Foot Pattern
Figure 2.16 shows how to connect a 128-pin 0.5mm pitch foot pattern on the user system to the M3T-F160-128NRD (not
included), and here following is its procedure.
For details on the M3T-F160-128NRD (not included), refer to its user's manual.
(1) Attach the NQPACK128RD included with the M3T-F160-128NRD to the user system.
(2) Attach the YQPACK128RD included with M3T-F160-128NRD to the NQPACK128RD and secure it with the
YQ-GUIDE's.
(3) Attach the CN2 side of the M3T-F160-128NRD to the CN2 side of the package converter board connected to the emulation
pod probe.
(4) Attach the M3T-F160-128NRD to the YQPACK128RD.
*
CN2 side
(3)
(1)
128-pin 0.5mm pitch
(PLQP0128KB-A) foot pattern
No. 1 pin
User system
M3T-F160-128NRD
(not included)
FLASH MCU, etc.
On-board evaluation
*: These four items are available in one package.
YQPACK128RD
NQPACK128RD
HQPACK128RD
(not included)
(2)
(4)
YQ-GUIDE (x4)
These corners are not round.
Package converter board
Tip of emulation pod probe
Figure 2.16 Connecting to a 128-pin 0.65mm pitch foot pattern
CAUTION
Note on Connecting the User System:
z Take care not to attach the converter board in a wrong direction. It may cause a fatal damage to the emulation
pod.
IMPORTANT
Note on Connectors of the Converter board:
z The connectors of the M3T-F160-128NRD are guaranteed for only 50 insertion/removal iterations.