Introduction
The VW3A58101 display module is supplied with ATV58••••M2 and ATV58••••N4 speed controllers.
ATV58••••••Z speed controllers are supplied without a display module. This can be ordered separately.
Installing the display module on the speed controller :
The protective cover should be removed before installing the display module on an ATV58••••••Z speed
controller.
The display module must be connected and disconnected with the power off. If the display module is
disconnected when control of the speed controller via the display module is enabled, the speed controller locks
in fault mode SLF.
Installing the display module remotely :
Use the kit, reference VW3A58103, comprising 1 cable with connectors, the parts required for mounting on an
enclosure door and the installation guide.
Signaling on the front panel of the Altivar
Other LEDs, indicating status with communication option cards.
Green LED POWER on : Altivar powered up
Red LED FAULT on : Altivar faulty
flashing : Altivar locked once the "STOP" key has
been pressed on the display module or after a
change to the configuration. The motor can then
only be supplied with power after resetting prior to
the "forward", "reverse", and "injection stop"
commands.
FAULT