Adjust Menu
The following parameters can be accessed in the ‘handling’ macro-configuration
(1) In corresponds to the speed controller nominal current indicated in the catalog and on the speed controller
identification label for "high torque" applications.
Code Description Adjustment range Factory setting
UU
UU
FF
FF
rr
rr
IR Compens. - %
0 to 150% or 0 to 800% 100%
Used to adjust the default value or the value measured during auto-tuning. The adjustment range is
extended to 800% if the SPC parameter (special motor) is set to “Yes” in the drive menu.
SS
SS
LL
LL
PP
PP
Slip Comp. - %
0 to 150% 100%
Used to adjust the slip compensation value fixed by the motor nominal speed.
SS
SS
PP
PP
22
22
Preset Sp.2 - Hz
LSP to HSP 10 Hz
2nd preset speed
SS
SS
PP
PP
33
33
Preset Sp.3 - Hz
LSP to HSP 15 Hz
3rd preset speed
SS
SS
PP
PP
44
44
Preset Sp.4 - Hz
LSP to HSP 20 Hz
4th preset speed
SS
SS
PP
PP
55
55
Preset Sp.5 - Hz
LSP to HSP 25 Hz
5th preset speed
SS
SS
PP
PP
66
66
Preset Sp.6 - Hz
LSP to HSP 30 Hz
6th preset speed
SS
SS
PP
PP
77
77
Preset Sp.7 - Hz
LSP to HSP 35 Hz
7th preset speed
CC
CC
tt
tt
dd
dd
Curr.Lev.Att - A
0 to 1.36 In (1) 1.36 In (1)
Current threshold above which the logic output or the relay changes to 1