Sun Microsystems V120 Server User Manual


 
Chapter 8 Managing the Server From the lom> Prompt 8-21
In this file the reports are displayed with a label identifying them as lom reports and
indicating their severity. The different levels of severity are, in descending order:
1. Fatal
These events might concern, for example, exceeded temperature thresholds or
supply rail failures. Fatal events may cause the server to shut itself down.
2. Warning
These events might concern fans turning too slowly, the Fault LED having been
turned on, or the System Configuration Card having been removed. They are not
events that cause the server to shut down, but they do require immediate attention.
3. Info
These events are most likely to inform you that some problem is now OK. For
example, if you re-insert the System Configuration Card, the LOM device will
generate an event to say that the System Configuration Card has been restored.
4. User
User level events concern the activity of named users whom you have authorized to
access the LOM device. For example, an event is generated when a user logs in or
out.
8.8 The LOM Shell Command List
The commands you can execute from the lom> prompt are listed in TABLE 8-2.
TABLE 8-2 LOM Commands
Command Effect
alarmoff n Sets alarm n off.
(Where n is 1, 2, or 3.) These three alarms are software flags. They are
associated with no specific conditions but are available to be set by
your own processes.
alarmon n Sets alarm n on.
See the description for the alarmoff command.
break Takes the server down to the ok prompt.
bootmode Determines the behavior of the server during the boot process.