Sun Microsystems V120 Server User Manual


 
Appendix C Configuring the LOM Device Driver C-5
Each parameter must be on a separate line and must befollowed by an equals sign
(=) and a value, without spaces. Where the format is Boolean, 1 means true and 0
means false.
serial_timeout= Multiples
of 4 secs
0 Specifies the idle period after
which the LOM device gives
control of the Serial A/LOM
port back to the console when it
has finished sending a report.
By default, there is no delay at
all. If you enable the
serial_return= option , the
serial_timeout= option
specifies the period that the
LOM waits after each LOMlite
command before giving control
of the Serial A/LOM port back
to the console. By default, there
is no delay.
serial_return= Boolean
0=FALSE
1=TRUE
0 Causes the LOM to return the
user to the console from the
lom> prompt after each LOM
shell command. You can use
this option in conjunction with
the serial_timeout= option.
reporting_level= Number
between 0
and 4
3 The severity level down to
which you want to see LOM
event reports. 0 means no
reports. 1 means Fatal event
reports only. 2 means Fatal and
Warning event reports. 3 means
Fatal, Warning and Information
event reports. 4 means Fatal,
Warning, Information and User
event reports. (User event
reports concern the user
security facility, you will not see
any unless you have enabled
the security facility and set up
users.)
TABLE C-1 LOM Configuration File Parameters (Continued)
Field Format Default Effect