9-6 Sun Fire V120 and Netra 120 Server User’s Guide • December 2001
● To configure the LOM device to perform an automatic server restart (ASR) after a
lockup, you must enable the Hardware reset option as well as the Watchdog
option. For information about how to do this, see Section 9.2, “Configuring
Automatic Server Restart (ASR)” on page 9-8.
9.1.8 Viewing the Configuration of the LOM Device
(lom -c)
● To view the settings of all the configurable variables for the LOM device, type:
9.1.9 Viewing All Component Status Data With the
LOM Device’s Configuration Data (lom -a)
● To view all the status data stored by the LOM device plus the details of the
device’s own configuration, type:
# lom -c
LOMlite configuration settings:
serial escape character=#
serial event reporting=default
Event reporting level=fatal, warning & information
Serial security=enabled
Disable watchdog on break=disabled
Automatic return to console=disabled
alarm3 mode=watchdog
firmware version=3.0
firmware checksum=2983
product revision=0.0
product ID=120
#
# lom -a