Sun Microsystems V120 Server User Manual


 
10-10 Sun Fire V120 and Netra 120 Server User’s Guide December 2001
Start the watch-net diagnostic test by typing the watch-net command at the ok
prompt. For the watch-net-all diagnostic test, type watch-net-all at the ok
prompt.
10.3 Solutions to Problems You Might
Encounter
Problem: Cannot Set Up a Console Connection to the Server
The Sun Fire V120 and Netra 120 servers’ serial port pinouts are listed in Chapter 6.
Check that they are correct for the device (that is, the terminal or terminal server)
that you are connecting to the server.
FIGURE 10-5 watch-net Diagnostic Output Message
{0} ok watch-net
Internal loopback test -- succeeded.
Link is -- up
Looking for Ethernet Packets.
‘.’ is a Good Packet. ‘X’ is a Bad Packet.
Type any key to stop.................................
FIGURE 10-6 watch-net-all Diagnostic Output Message
{0} ok watch-net-all
/pci@1f,0/pci@1,1/network@c,1
Internal loopback test -- succeeded.
Link is -- up
Looking for Ethernet Packets.
‘.’ is a Good Packet. ‘X’ is a Bad Packet.
Type any key to stop.