You can display statistics about a conference and use the information to quickly see how many participants are
currently in the conference.
To access this option:
1. Go to .
2. Click a Conference name and then click the tab.
If the conference is active, statistics for that conference will be displayed. If the conference is completed only ―No
longer active‖ will be displayed.
Refer to the table below for information on interpreting this information.
When the conference started.
When the conference will complete. This will be the time at which the maximum duration of
the conference will have elapsed. This setting displays as <permanent> if it has been
configured to last forever.
The duration of this conference.
The status of a conference with respect to its H.323 gatekeeper and/or SIP registrations. The
possible states are:
This conference is not configured to be registered with a gatekeeper or SIP registrar;
because of this, there is no applicable registration status to show.
The conference has been registered successfully with the gatekeeper or SIP registrar
and can be contacted using the number indicated.
This conference is in the process of registering with the gatekeeper or SIP registrar.
The conference is in the process of unregistering with the gatekeeper or SIP
registrar. This might occur if:
o Gatekeeper registration has been turned off (either for that conference only
or for the entire MCU)
o The configured gatekeeper has just been changed and the MCU is in the
process of unregistering from the previous gatekeeper before registering its
conferences with the new one.
If the MCU fails to register a conference with the gatekeeper or SIP registrar, it
enters these states temporarily before re-attempting the registration.
This ID has been specifically configured to be registered with the gatekeeper or SIP
registrar, but some other configuration has overridden this, causing the registration
to not be attempted. This state might occur if either of the H.323 gatekeeper usage or
ID registration for scheduled conferences options on the page is set
to Disabled.
The conference is configured to register with a gatekeeper or SIP registrar, but has
not had a numeric identifier set.