e-STUDIO281c/351c/451c ERROR CODE AND SELF-DIAGNOSTIC MODE June 2005 © TOSHIBA TEC
2 - 122
561 Image Process switching for
image smoothing (Photo)
PPC
(black)
0
<0-1>
M Sets whether or not
performing a smooth-
ing process (primary
scanning direction,
2,400 dpi or equiva-
lent).
0: Invalid
1: Valid
1
562 Image Process switching for
image smoothing (Text)
PPC
(black)
1
<0-1>
M1
565 Image
control
Image quality closed-loop
control automatic start-up/
Relative humidity variation
ALL
(color)
1
<0-2>
M Sets whether or not
performing closed-loop
control automatically
when the relative
humidity becomes
below the specified
level from the previous
control.
0: Invalid
1: Valid (at mode 1)
2: Valid (at mode 2)
1
566 Image
control
Image quality closed-loop
control automatic start-up/
Period of time unattended
ALL
(color)
1
<0-2>
M Sets whether or not
performing closed-loop
control automatically
when the equipment
has not been used for a
specified period of time.
0: Invalid
1: Valid (at mode 1)
2: Valid (at mode 2)
1
567 Image
control
Image quality closed-loop
control automatic start-up/
Accumulated print volume
ALL
(color)
2
<0-2>
M Sets whether or not
performing closed-loop
control automatically
when the specified
number of sheets has
been printed out from
the previous control.
0: Invalid
1: Valid (at mode 1)
2: Valid (at mode 2)
1
568 Image
control
Image quality closed-loop
control automatic start-up/
When recovered from
“Toner empty”
ALL
(color)
2
<0-2>
M Sets whether or not
performing closed-loop
control automatically
when recovered from
“Toner empty”.
0: Invalid
1: Valid (at mode 1)
2: Valid (at mode 2)
1
Setting mode (08)
Code
Classifi-
cation
Items
Func-
tion
Default
<Accept-
able
value>
RAM Contents
Pro-
cedur
e