Toshiba e-STUDIO451c Copier User Manual


 
e-STUDIO281c/351c/451c ADJUSTMENT June 2005 © TOSHIBA TEC
3 - 42
3.7.2 Density adjustment (Black Mode)
Adjusts the center density and the variation of density adjustment buttons.
<Adjustment Mode (05)>
<Procedure>
(1) While pressing [0] and [5] simultaneously, turn the power ON.
(2) Key in a code and press the [START] button.
(3) Key in an adjustment value (acceptable values: 0 to 255).
(To correct the value once keyed in, press the [CLEAR] button.)
(4) Press the [ENTER] or [INTERRUPT] button to store the value in memory. Æ The equipment goes
back to the ready state.
(5) Let the equipment restart and perform scanning job.
(6) If the desired image has not been attained, repeat step (1) to (5).
Color
mode
Original mode
Item to be
adjusted
Remarks
Text/Photo Text Photo
Black 845 846 847 Manual density
center value
The larger the value is, the darker the
image becomes.
Acceptable values: 0 to 255
(Default: 128)
855 856 857 Manual density
dark step value
The larger the value is, the darker the
dark side becomes.
Acceptable values: 0 to 255
(Default: 20)
850 851 852 Manual density
light step value
The larger the value is, the lighter the
light side becomes.
Acceptable values: 0 to 255
(Default: 20)
860 861 862 Automatic density The larger the value is, the darker the
image becomes.
Acceptable values: 0 to 255
(Default: 128)