Worth Data 802 RF Credit Card Machine User Manual


 
7-5
You need 2 cables to clone 802 RF Terminals; the Data Cloning Cable
#F38 and the Voice Cloning Cable #T15. The Data Cloning Cable plugs
into the “Computer” port on each 802 RF Terminal. This cable must be
connected to clone properly.
One jack on the Voice Cloning Cable has two black rings on it – this end
must plug in to the RECEIVING 802 RF Terminal (the one you are
transmitting to). Plug the single-banded jack end into the MASTER 802 RF
Terminal (the one you are going to record from).
Once both cables are plugged in to both Terminals, go to the Setup Menu on
both Terminals. Select 3 for Voice Operations from the menu.
The “Receiving” 802 RF Terminal must be started first. On the receiving
Terminal, press the 4 key for Cloning Receiver. The “Receiving” unit will
display:
Recv Setup/Voice
Please Wait_
Now you can start the “Master” 802 RF Terminal by pressing the 3 key for
Cloning Master. The “Master” Terminal will display:
Xmit Setup/Voice
Please Wait_
During the cloning process, you will hear the voice messages played aloud
as they are copied. The process takes about 75 seconds to complete. After
the Terminals are done cloning, they will both display:
End of Cloning
Hit Any Key_
If you did not hear the correct messages or you heard no messages at all,
check your cables and receiver/master setup - you may have transmitted
from the wrong 802 RF Terminal.
DATA XMIT ERROR
CYCLE POWER
If you get the DATA XMIT ERROR message, you have to restart the whole
cloning procedure.