Worth Data 802 RF Credit Card Machine User Manual


 
8-3
Terminal Error Messages
Message Meaning – Action Required
Looking for App Server
Please Wait
This is a normal message, generated when the
Terminal Device first tries to establish contact with a
Server.
TERMINAL OUT OF
RANGE, PRESS ANY KEY
TO RETRY
The Terminal is not within range of any Access Point –
regardless of SSID or encryption settings. Move closer
or hold up to retry. If persistent, do a Site Survey.
Server Not Available
Press Any Key
Terminal is configured to search for Application Server,
but it could not find it.
Looking for DHCP Server
Please Wait
Terminal is configured to get its IP address from a
DHCP Server. It is broadcasting search.
No DHCP Server Found
Terminal is configured to obtain IP Address from DHCP
Server, but it could not find a DHCP Server
WAITING ON HOST
PROMPT, Please Wait
The Server has been found. The host program has not
sent out a prompt yet. If this lasts more than 6 seconds,
check the host application program for a logic bug.
Transmission Delayed,
Press Any Key
This is an indication that the Radio was reset by the
firmware – normally a rare condition. If you see it more
than once per week, please call us with information on
what you were doing at the time it occurred.
Server Shut Down Due to
Host Logic Error,
Press Any Key
Problem is in host program. Notify programmer!
If the Server detects 5 Sequence Errors in a row, or 5
messages to a Terminal not Signed In, or 5 Illegal
Commands, the Server transmits the message to all
terminals signed in and shuts down. Check your host
program and correct the logic error before starting up
again.
Server Re-initialized
Press Any Key
The Server was rebooted. Press any key to be
transferred to the Mode menu.
LOW BATTERIES
Finish, Sign Off
Change Batteries
Finish the transaction you have started. The Press F1
to Sign Out. Then turn off the Terminal and change the
batteries.
CHANGE BATTERIES
UNIT SHUT DOWN
The terminal will display this message for 20 seconds,
sign out, and turn off.
Change the batteries immediately. Don’t let someone
else pick it up and operate with partially recovered
batteries
Cannot Communicate with
PIC Processor
The Terminal cannot communicate with the radio's PIC
processor. Cycle power. If message persists, call for
RMA.
Radio not Responding
The terminal's radio is not responding, Call for an RMA.