ZyXEL Communications 202H Network Card User Manual


 
Prestige 202H User’s Guide
5-4 ISDN Setup
5.2.1 Configuring Advanced Setup
Figure 5-3 Menu 2 ISDN Setup for DSS1
When you are finished, press [ENTER] at the message: ‘Press ENTER to confirm’, the router uses the
information that you entered to initialize the ISDN line. It should be noted that whenever the switch type is
changed, the ISDN initialization takes slightly longer.
At this point, the router asks if you wish to test your ISDN. If you select Yes, the router will perform a loop-
back test to check the ISDN line. If the loop-back test fails, please note the error message that you receive
and take the appropriate troubleshooting action.
Figure 5-4 Loopback Test
.
Menu 2.1 - ISDN Advanced Setup
Calling Line Indication= Enable
PABX Outside Line Prefix=
PABX Number (Include S/T Bus Number) for Loopback=
Outgoing Calling Party Number:
ISDN Data = 80010029
Data Link Connection= point-to-multipoint
Press ENTER to Confirm or ESC to Cancel:
Setup LoopBack Test ...
Dialing to 40000// ...
Sending and Receiving Data ...
Disconnecting ...
LoopBack Test OK
### Hit any key to continue. ###