The average sample position for the data lines during these read bursts is 2.25ns. This
Eye Finder measurement was taken with a read delay line setting of 1.8ns. You now
have enough information to calculate what an optimal read delay setting would be to
capture both read and write bursts. Proceed to Step 4 to do this.