Upgrading an Enterprise 3000 to CMS R3V9
44 CentreVu CMS R3V9 Sun Enterprise 3000 Computer CVUE Instructions
3. Enter:
metadb -i
The system displays a message similar to the following:
This command shows the database replicas. There should be four replicas for the boot
disk. If the correct number of replicas are not shown, escalate using the normal
channels.
4. Continue with Checking the status of the tape drives.
Checking the status of the tape drives
To check the status of the tape drives:
1. Enter:
ls -x /dev/rmt
The system displays a list of the current tape device modes for each installed tape
drive. If there is only one tape drive, a series of files starting with 0 is displayed. The
following example shows a series of files starting with 0. This indicates that there is
one tape drive installed on the system.
2. Note whether or not the number of tape drives that is displayed matches the number of
tape drives that are connected to the system.
3. Continue with Verifying that the upgrade can continue.
flags first blk block count
a m p luo 16 1034 /dev/dsk/c0t0d0s1
a p luo 1050 1034 /dev/dsk/c0t0d0s1
a p luo 2084 1034 /dev/dsk/c0t0d0s1
a p luo 3118 1034 /dev/dsk/c0t0d0s1
0 0b 0bn 0c 0cb 0cbn 0cn 0h 0hb 0hbn 0hn 0l 0lb
0lbn 0ln 0m 0mb 0mbn 0mn 0n 0u 0ub 0ubn 0un