64 CentreVu CMS R3V9 Sun Enterprise 3000 Computer CVUE Instructions
Checking the status of the disks
After migrating the customer’s data, you should verify that the disks have resynchronized
successfully before leaving the site.
To check the status of the disk drives:
1. Enter:
. /opt/informix/bin/setenv
2. Enter:
onstat -d | egrep “PD|R|X” | pg
The system should not display anything except the command prompt.
If any lines display MX or NX, the disk requires maintenance. Escalate through normal
channels.
If one or more lines display with PD or MR, the disks either need resyncing or are
currently resyncing. If any disks are still resyncing, you should continue to check the
system and run the onstat command to verify that the disks are in a stable state.
Replacing the customer’s tapes
After migrating the customer’s data, remove the tapes from the tape drives, and replace
any tapes that the customer originally had in the tape drives. These tapes may be used for
scheduled backups and must be replaced before leaving the customer site.