Avaya Comcode 700220627 Laptop User Manual


 
Upgrading the system
Issue 3.0 February 2002 65
Troubleshooting upgrade failures
If you receive an error message that one of the installation scripts failed when you run the
cvue_activate command, you may be able to recover and continue with the upgrade.
Some of the installation scripts can be skipped during this part of the upgrade. However,
any script that is skipped during this part of the upgrade must be installed later using the
standard software installation procedures found in the CMS software installation
document.
The following table lists all of the possible software installation scripts, and explains what to
do if one of them fails during the upgrade. When identifying the installation scripts, be
aware that each script is numbered with a prefix (for example, S04) before the script name.
Script name Description How to recover
install_sql ISQL software All of these scripts install optional software or
drivers needed by the customer. You can skip the
script and reinstall the software later. To skip the
script:
1. Enter: cd /adminsave/init.d
2. Enter: mv
scriptname
/adminsave/ where
scriptname
is the name of the script.
3. Enter: cd /cdrom/cdrom0
4. Run the ./cvue_activate command again.
5. Install the software package that you skipped
before you migrate the customer’s data.
After each script is executed, a copy of the script is
moved to /adminsave/init.d.completed.
x25_setup Set up X.25
install_nts NTS drivers
install_hsip HSI/P drivers
install_hsis HSI/S drivers
install_saip SAI/P drivers
install_saipu SAI/P utilities
install_tokenring_s Token Ring software
install_tokenring_p Token Ring software
install_odbcX_X ODBC software