Black Box Hardened Managed Ethernet Switche Computer Hardware User Manual


 
724-746-5500 | blackbox.com
Page 128
Chapter 7: Command-Line Management
4. Example:
The following example sets high power priority to the interface fe1 (port 1):
switch_a(config)#interface fe1
switch_a(config-if)#poe power-priority high
switch_a(config-if)#
Power Down Alarm:
1. Command Mode: Interface mode
Logon to Configure Mode (Configure Terminal Mode).
Then logon to Interface mode.
fe1 means port 1.
The switch_a(config-if)# prompt will show on the screen.
switch_a(config)#interface fe1
switch_a(config-if)#
2. Usage:
Use poe power-down-alarm enable command to enable power down alarm to this port.
Use the no poe power-classification enable to disable this function.
3. Command Syntax:
(no) poe power-down-alarm enable
4. Example:
The following example shows the use of poe power-down-alarm enable to the interface fe1 (port 1):
switch_a(config)#interface fe1
switch_a(config-if)#poe power-down-alarm enable
switch_a(config-if)#
PoE Scheduling (for LEH1000 Series Switches)
PoE Schedule:
1. Command Mode: Interface mode
Logon to Configure Mode (Configure Terminal Mode).
Then logon to Interface mode.
fe1 means port 1.
The switch_a(config-if)# prompt will show on the screen.
switch_a(config)#interface fe1
switch_a(config-if)#
2. Usage:
Use this command to enble PoE scheduling to this port.