724-746-5500 | blackbox.com
Page 77
Chapter 6: Web-Based Browser Management
6.13 LLDP
Figure 6-67.
LLDP General Settings
1. LLDP: From the “LLDP” drop-down list, choose “Enable” or “Disable” to enable or disable Link Layer Discovery Protocol (LLDP)
globally.
2. Holdtime multiplier (2-10): Click in the “Holdtime multiplier” textbox and set the Link Layer Discovery Protocol (LLDP) holdtime
multiplier value. The transmit interval is multiplied by the holdtime multiplier to give the Time To Live (TTL) that the switch
advertises to the neighbors. Enter a Holdtime multiplier value in the range from 2 to 10. Default is 4.
3. Tx Interval (5-32768 seconds): Click in the “Tx Interval” text box and set the transmit interval. This is the interval between
regular transmissions of Link Layer Discovery Protocol (LLDP) advertisements. Enter a Tx Interval value in the range from 5 to
32768. Default is 30 seconds.
4. Global TLV setting: Click and choose Link Layer Discovery Protocol (LLDP) Type Length Value (TLV) setting.
5. Update Setting: Click on the “Update Setting” button when you finish LLDP General Settings.