Black Box Hardened Managed Ethernet Switche Computer Hardware User Manual


 
724-746-5500 | blackbox.com
Page 158
Chapter 7: Command-Line Management
switchport trunk allowed vlan except VLANID
no switchport trunk vlan
all Allow all VLANs to transmit and receive through the Layer-2 interface.
none Allow no VLANs to transmit and receive through the Layer-2 interface.
add Add a VLAN to transmit and receive through the Layer-2 interface.
remove Remove a VLAN from transmit and receive through the Layer-2 interface.
except All VLANs, except the VLAN for which the ID is specified, are part of its ports member set.
VLANID <2-4094> The ID of the VLAN or VLANs that will be added to, or removed from, the Layer-2 interface. A single VLAN,
VLAN range, or VLAN list can be set.
For a VLAN range, specify two VLAN numbers: lowest, then highest number in the range, separated by a hyphen.
For a VLAN list, specify the VLAN numbers separated by commas.
4. Example:
The following example specifies to add the interface fe1 (port 1) to VLANID (2):
switch_a(config)#interface fe1
switch_a(config-if)#switchport trunk allowed vlan add 2
switch_a(config-if)#
Priority Level:
1. Command Mode: Interface mode
Logon to Configure Mode (Configure Terminal Mode).
Then logon to Interface mode.
fe1 means port 1.
The switch_a(config-if)# prompt will show on the screen.
switch_a(config)#interface fe1
switch_a(config-if)#
2. Usage:
Use this command to set user priority for port.
3. Command Syntax:
user-priority <0-7>
<0-7> User priority value.
4. Example:
The following example sets user priority (0) for the interface fe1 (port 1):
switch_a(config)#interface fe1
switch_a(config-if)#user-priority 0