Brady X-Plus II Printer User Manual


 
Routine Maintenance
Replace the Fuse (360X-Plus II Only)
134
14068L-001 Rev. A X-Plus II User Guide 1/11/07
Replace the Fuse (360X-Plus II Only)
The instructions that follow are for the 360X-Plus II series printers only. The 300X-Plus II and
600X-Plus II fuses are not user-replaceable.
The printer uses a metric-style fuse (5 × 20 mm IEC) rated at F5A, 250 V. The AC power entry
module comes with two approved fuses in the fuse holder: one is in-circuit, and the second is
provided as a spare. The end caps of the fuse must bear the certification mark of a known
international safety organization (see Figure 11 on page 25).
To replace a faulty fuse, complete these steps:
1. Use a small-blade screwdriver or similar tool to remove the fuse holder.
The fuse holder is part of the AC power entry module at the rear of the printer (Figure 36).
Figure 36 • AC Power Entry Module
2. Remove the faulty fuse and install a new fuse in the in-circuit position (Figure 37).
Caution • Turn the AC power switch off (O) and remove the power cord before performing
this procedure.
1
Power switch
2
Fuse holder
3
AC power entry module
4
Small-blade screwdriver
Important • If you use the spare fuse, be sure to order a replacement fuse from an
authorized Brady distributor. The spare fuse should be the exact type and rating as the
original in-circuit fuse.
1
2
3
4