Brady X-Plus II Printer User Manual


 
Configuration
Control Panel Parameters
86
14068L-001 Rev. A X-Plus II User Guide 1/11/07
Set Applicator Port Mode
Determines the action of the applicator port.
Note • Set this value as suggested by the applicator manufacturer.
Default: OFF
Selections: OFF, MODE 1, MODE 2, MODE 3, MODE 4
OFF: The applicator port is off.
MODE 1: Asserts the ~END_PRINT signal low while the printer is
moving the label forward.
MODE 2: Asserts the ~END_PRINT signal high while the printer is
moving the label forward.
MODE 3: Asserts the ~END_PRINT signal low for 20 milliseconds
when a label has been completed and positioned. Not asserted during
continuous printing modes.
MODE 4: Asserts the ~END_PRINT signal high for 20 milliseconds
when a label has been completed and positioned. Not asserted during
continuous printing modes.
To change the value shown:
1. Press the left or right oval to scroll through the options.
Select Start Print Signal
This parameter determines how the printer reacts to the Start Print Signal
input on pin 3 of the applicator interface connector at the rear of the printer.
Caution • Start Print Signal is set by the applicator manufacturer and
should not be changed unless the factory defaults have been reloaded.
Please make a note of it. While other choices are valid, the printer must
be returned to its designated setting for it to work properly.
Default: PULSE MODE
Selections: PULSE MODE, LEVEL MODE
PULSE MODE—Labels print when the signal transitions from
HIGH to LOW.
LEVEL MODE—Labels print as long as the signal is asserted LOW.
To change the value shown:
1. Press the left or right oval to toggle between the options.
Table 9 • Printer Parameters (Sheet 23 of 26)
Parameter
Action/Explanation
APPLICATOR PORT
- OFF +
START PRINT SIG
- PULSE MODE +