Brady X-Plus II Printer User Manual


 
Configuration
Control Panel Parameters
84
14068L-001 Rev. A X-Plus II User Guide 1/11/07
Set the Head Test Count
The printer periodically performs a test of the printhead functionality,
called a printhead test or head test. This parameter establishes how many
labels are printed between these internal tests.
Note • This parameter will only appear if the Head Test Count
option is installed. This option is available only on the BP-360X-
Plus II.
Default: 0000 (disables the test)
Range: 0000 to 9999
To set the number of labels to print between head tests:
1. Press the left oval to move to the next digit position.
2. Press the right oval to increase the value of the digit.
Table 9 • Printer Parameters (Sheet 21 of 26)
Parameter
Action/Explanation
HEAD TEST COUNT
- 0000 +
If the Head Test Option is
installed, HEAD TEST COUNT
will be listed.