114 Troubleshooting
Virtual Disks Offline Error Message
Error Message: x Virtual Disk(s) Offline, where x is the number of
virtual disks failed.
Probable Cause: This warning is displayed when the BIOS detects virtual
disks in the offline state.
Corrective Action: You must check to determine why the virtual disks failed
and correct the problem. The BIOS does not take any action.
Virtual Disks Degraded Error Message
Error Message: x Virtual Disk(s) Degraded, where x is the number
of virtual disks degraded.
Probable Cause: This message is displayed when the BIOS detects virtual
disks in a degraded state.
Corrective Action: Take corrective action(s) to make the virtual disks
optimal. The BIOS does not take any action.
Virtual Disks Partially Degraded Error Message
Error Message: x Virtual Disk(s) Partially Degraded, where
x is the number of virtual disks partially degraded
.
Probable Cause: This message is displayed when the BIOS detects a single
disk failure in a RAID 6 or RAID 60 configuration
.
Corrective Action: You must check why the member disk is not present to
correct the problem. The BIOS does not take any action.
Memory or Battery Problem Error Message
Error Message: Memory/Battery problems were detected. The
adapter has recovered, but cached data was lost. Press
any key to continue.
Probable Cause: The message occurs under the following conditions:
The adapter detects data in the controller cache that has not yet been
written to the disk subsystem.
The controller detects an Error-Correcting Code (ECC) error while
performing its cache checking routine during initialization.