Dell H710 Server User Manual


 
98 CacheCade
Manual Resizing of CacheCade Virtual Disks
In operating system management applications, a manual resizing of a
CacheCade virtual disk occurs due to the addition or removal of drives.
Reboot is not be necessary.
Any number of SSDs can be added to a CacheCade virtual disk.
There is no SAS and SATA mixing allowed within a CacheCade virtual
disk, so SATA SSDs cannot be added to a SAS CacheCade virtual disk and
vice versa.
HDDs cannot be added to a CacheCade virtual disk.
NOTE: Capacity of drives added to a CacheCade volume must be equal to or
greater than the smallest contributing drive in the virtual disk. The manual resizing
of a CacheCade virtual disk cannot be initiated in the BIOS configuration utility. It
can only be initiated in the OpenManage storage management application.