Troubleshooting 117
Multibit ECC Errors Detected Error Messages
NOTE: The following error is specific to the PERC H710 controller only.
Error Message: Multibit ECC errors were detected on the
RAID controller. If you continue, data corruption can
occur. Contact technical support to resolve this
issue. Press 'X' to continue or else power off the
system, replace the controller and reboot.
Or
Error Message: Multibit ECC errors were detected on the
RAID controller.The DIMM on the controller needs
replacement. If you continue, data corruption can
occur. Press 'X' to continue or else power off the
system, replace the DIMM module, and reboot. If you
have replaced the DIMM please press 'X' to continue.
CAUTION: Multi-bit ECC errors cause data corruption and data loss. In case of
MBE errors, contact Dell Technical Support.
Probable Cause: Multi-bit ECC errors occur in the memory and can corrupt
cached data and discard it.
Corrective Action: Contact Dell Technical Support.
Configured Disks Removed or Not Accessible Error Message
Error Message: Some configured disks have been removed
from your system or are no longer accessible. Check
your cables and ensure all disks are present. Press
any key or ’C’ to continue.
Probable Cause: The message indicates that some configured disks were
removed. If the disks were not removed, they are no longer accessible. The
SAS cables for your system might be improperly connected.
Corrective Action: Check the cable connections and fix any problems.
Restart the system. If there are no cable problems, press any key or <C> to
continue.