Dell H710 Server User Manual


 
66 Management Applications for PERC Cards
c
Select
Import
to merge the foreign configurations with the existing
configuration on the controller or
Clear
to delete the foreign
configuration(s) from the re-inserted disk(s).
If you select
Import
, all drives that were pulled before the virtual disk
became offline are imported, and then automatically rebuilt.
NOTE: Start a consistency check immediately after the rebuild is
complete to ensure data integrity for the virtual disks. For more information
about checking data consistency, see "Checking Data Consistency" on
page 62.
3
If the physical disks in a non-redundant virtual disk are removed,
the controller considers the disks to have foreign configurations.
Perform the following steps:
a
Select
Foreign Configuration View to
display the complete foreign
configuration information.
b
Press <F2> to display the options
Import
and
Clear
.
c
Select
Import
to import the foreign configuration to the virtual disk or
Clear
to delete the foreign configuration(s) from the re-inserted
disk(s).
No rebuilds occur after the import operation because there is no
redundant data to rebuild the disks with.
Break Mirror
A Break Mirror operation is an operation that can be performed only on
RAID1 arrays. It provides a way to 'split' the mirror and spin-down one of the
hard disks, which can then be imported into the configuration of a different
PERC H310, H710, H710P, or H810 controller. This can be a useful way to:
Create a disk image that can be imported and booted on a different
system.
Assist in software or configuration testing, where half of the mirror can be
removed to ensure configuration consistency.
NOTE: The Break Mirror operation is not available within the booted
operating system environment. It is only available in the BIOS (Ctrl-R) utility
and the UEFI RAID configuration utility.