166 Troubleshooting Your System
9
Reseat the memory modules in their sockets. See "Installing Memory
Modules" on page 108.
10
Replace the cooling shroud. See "Installing the Cooling Shroud" on
page 87.
11
Close the system. See "Closing the System" on page 85.
12
Reconnect the system to its electrical outlet, and turn on the system
and attached peripherals.
13
Enter the System Setup program and check the system memory setting.
See "Memory Settings Screen" on page 61.
If the problem is not resolved, proceed with the next step.
14
Turn off the system and attached peripherals, and disconnect the system
from the power source.
15
Open the system. See "Opening the System" on page 83.
16
If a diagnostic test or error message indicates a specific memory module
as faulty, swap or replace the module.
17
To troubleshoot an unspecified faulty memory module, replace the
memory module in the first DIMM socket with a module of the same type
and capacity. See "Installing Memory Modules" on page 108.
18
Close the system. See "Closing the System" on page 85.
19
Reconnect the system to its electrical outlet, and turn on the system and
attached peripherals.
20
As the system boots, observe any error message that appears and the
diagnostic indicators on the front of the system.
21
If the memory problem is still indicated, repeat step 14 through step 20 for
each memory module installed.
If the problem persists after all memory modules have been checked,
see "Getting Help
" on page 187
.
book.book Page 166 Tuesday, August 24, 2010 1:47 PM