Dell R515 Computer Hardware User Manual


 
50 About Your System
Thermal sensor
not detected
on x
A memory module without a
thermal sensor is installed in
the specified memory slot.
Replace the memory
module. See "System
Memory" on page 104.
Time-of-day
clock stopped
Faulty battery or faulty chip. See "Troubleshooting the
System Battery" on page 162.
Time-of-day not
set - please run
SETUP program
Incorrect Time or Date
settings; faulty system
battery.
Check the Time and Date
settings. See "Using the
System Setup Program and
UEFI Boot Manager" on
page 57. If the problem
persists, replace the system
battery. See "System Battery"
on page 133.
Timer chip
counter 2 failed
Faulty system board. See "Getting Help" on
page 187.
TPM
configuration
operation
honored. System
will now reset.
A TPM configuration
command has been entered.
The system reboots and
executes the command.
Information only.
TPM
configuration
operation is
pending. Press
(I) to Ignore
OR (M) to Modify
to allow this
change and reset
the system.
WARNING:
Modifying could
prevent
security.
This message displays during
system restart after a TPM
configuration command has
been entered. User
interaction is required to
proceed.
Enter I or M to proceed.
TPM failure A Trusted Platform Module
(TPM) function has failed.
See "Getting Help" on
page 187.
Message Causes Corrective Actions