Dell R515 Computer Hardware User Manual


 
38 About Your System
E2112 Memory spared
on DIMM ##.
Power cycle
AC.
The system BIOS has
spared the memory
because it has determined
the memory had too many
errors. "##" represents the
memory module
implicated by the BIOS.
Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists,
see "Troubleshooting
System Memory" on
page 165.
I1910 Intrusion
detected.
Check chassis
cover.
System cover has been
removed.
Information only.
I1912 System Event
Log full.
Review &
clear log.
The SEL is full of events
and is unable to log any
more.
Check the SEL for details
on the events, then clear
the SEL.
I1920 iDRAC6 Upgrade
Successful
Optional iDRAC6 has
been upgraded
successfully.
Information only.
W1228 RAID
Controller
battery
capacity <
24hr.
Warns predictively that
the RAID battery has
less than 24 hours of
charge left.
Allow RAID battery
to charge to greater
than 24 hours of
sustained charge.
If problem persists,
replace RAID battery.
See "Installing the RAID
Battery" on page 137.
W1627 Power required
> PSU wattage.
Check PSU and
config.
The system configuration
requires more power
than what the power
supply can provide.
Turn off power to the
system, reduce the
hardware configuration or
install higher-wattage
power supplies, and then
restart the system.
Code Text Causes Corrective Actions
book.book Page 38 Tuesday, August 24, 2010 1:47 PM