Dell R515 Computer Hardware User Manual


 
About Your System 37
E201E POST memory
test failure.
Check DIMMs.
BIOS POST memory test
failure.
See "Troubleshooting
System Memory" on
page 165.
If the problem persists,
see "Getting Help" on
page 187.
E2020 CPU
configuration
failure. Check
screen
message.
Processor configuration
failure.
Check screen for specific
error messages.
See "Troubleshooting
Processors" on page 174.
E2021 Incorrect
memory
configuration.
Review User
Guide.
Incorrect memory
configuration.
Check screen for specific
error messages. See
"Troubleshooting System
Memory" on page 165.
E2022 General
failure
during POST.
Check screen
message.
General failure after video. Check screen for specific
error messages.
E2110 Multibit Error
on DIMM ##.
Reseat DIMM.
The memory module in
slot “##” has had a
multi-bit error (MBE).
See "Troubleshooting
System Memory" on
page 165.
E2111 SBE log
disabled on
DIMM ##.
Reseat DIMM.
The system BIOS has
disabled memory
single-bit error (SBE)
logging and does not log
anymore SBEs until the
system is rebooted. "##"
represents the memory
module implicated by
the BIOS.
Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists,
see "Troubleshooting
System Memory" on
page 165.
Code Text Causes Corrective Actions
book.book Page 37 Tuesday, August 24, 2010 1:47 PM