Dell R515 Computer Hardware User Manual


 
28 About Your System
E1114 Ambient Temp
exceeds
allowed range.
Ambient temperature has
a reached a point outside
of the allowed range.
See "Troubleshooting
System Cooling
Problems" on page 163.
E1116 Memory
disabled,
temp above
range.
Power
cycle AC.
Memory has exceeded
allowable temperature and
has been disabled to
prevent damage to the
components.
Remove AC power to the
system for 10 seconds and
restart the system.
See "Troubleshooting
System Cooling
Problems" on page 163.
If the problem persists,
see "Getting Help" on
page 187.
E1210 Motherboard
battery
failure.
Check
battery.
CMOS battery is missing
or the voltage is outside of
the allowable range.
See "Troubleshooting the
System Battery" on
page 162.
E1211 RAID
Controller
battery
failure.
Check
battery.
RAID battery is either
missing, bad, or unable
to recharge due
to thermal issues.
Reseat the RAID battery
connector. See "Installing
the RAID Battery" on
page 137, and
"Troubleshooting System
Cooling Problems" on
page 163.
E1216 3.3V Regulator
failure.
Reseat PCIe
cards.
3.3 V voltage regulator
has failed.
Remove and reseat the
PCIe expansion cards.
If the problem persists,
see "Troubleshooting
Expansion Cards" on
page 172.
E1229 CPU # VCORE
Regulator
failure.
Reseat CPU.
Specified processor
VCORE voltage
regulator has failed.
Reseat the processor(s).
See "Troubleshooting
Processors" on page 174.
If the problem persists,
see "Getting Help" on
page 187.
Code Text Causes Corrective Actions