Ethernet 2, PMC/SBC Mode, and P2 I/O Selection Headers (J6, J7, J28, J32, J34, J97 – J110) Connector Pin
MVME55006E Single-Board Computer Installation and Use (6806800A37D)
91
5.3.1.3 P2 I/O Selection
Nine 3-pin 2 mm planar headers are for P2 I/O selection. Install jumpers across pins 1-2 on all
nine headers to select PMC 2 I/O for P2 in PMC mode. Install jumpers across pins 2-3 on all
nine headers to select IPMC I/O for P2 in SBC/IPMC761 or SBC/IPMC712 mode. The pin
assignments for these headers are as follows:
Table 5-23 P2 I/O Selection Headers (J102 – J110) Pin Assignments
Pin Signal Pin Signal
J102 J103
1 PMC2_IO (2) 1 PMC2_IO (5)
2 P2_PMC2_IO (2) 2 P2_PMC2_IO (5)
3 IPMC_DB8_L 3 IPMC_DB9_L
J104 J105
1 PMC2_IO (8) 1 PMC2_IO (11)
2 P2_PMC2_IO (8) 2 P2_PMC2_IO (11)
3 IPMC_DB10_L 3 IPMC_DB11_L
J106 J107
1 PMC2_IO (14) 1 PMC2_IO (17)
2 P2_PMC2_IO (14) 2 P2_PMC2_IO (17)
3 IPMC_DB12_L 3 IPMC_DB13_L
J108 J109
1 PMC2_IO (20) 1 PMC2_IO (23)
2 P2_PMC2_IO (20) 2 P2_PMC2_IO (23)
3 IPMC_DB14_L 3 IPMC_DB15_L
J110
1 PMC2_IO (26)
2 P2_PMC2_IO (26)
3 IPMC_DBP1_L