Epson GT-10000 Scanner User Manual


 
A-4
Technical Specifications
R4C345
Rev. C
A5 size APP_A.FM
10/7/99 Pass 0
L
Proof Sign-off:
<tantoname> SEI K.Ito M.Fujimori
<leadername> M.Fujimori
<editorname> SEI G.Hildebrand
Electrical
Note:
Check the label on the back of the scanner for voltage information.
Environmental
Temperature:
Operation 5° C to 35° C (41° F to 95° F)
Storage –25° C to 60° C (–13° F to 140° F)
Humidity:
Operation 10% to 80%, without condensation
Storage 10% to 85%, without condensation
Operating conditions: Ordinary office or home conditions.
Extreme dust should be avoided.
Operation under direct sunlight or near a
strong light source should be avoided.
Note:
Specifications are subject to change without notice.
100 to 120 V AC 220 to 240 V AC
Input voltage range AC 90 to 132 V AC 198 to 264 V
Rated frequency 50 to 60 Hz
Input frequency 49.5 to 60.5 Hz
Rated current 1.2 A 0.7 A
Power consumption Approx. 50 W without option
Approx. 55 W with option