To perform a soft reset of the switcher:
1. Use a small Philips screwdriver to press and hold the rear panel Reset button until
the front panel Video and Audio buttons blink once (for an events reset), twice (for a
system reset), or three times (for an absolute reset).
I / O
VIDEO AUDIO
RESET
RESET
RESET
I / O
AUDIO
RESET
RESET
RESET
I / O
VIDEO AUDIO
RESET
RESET
RESET
Release, then immediately
press and release again.
VIDEO
Release, then immediately
press and release again.
IP Settings
Reset
(Level 4)
6 seconds
Absolute Reset
(Level 5)
9 seconds
Press and hold
the Reset button.
3 seconds
Events Reset
(Level 3)
Front panel I/O buttons flash once.
Reset LED flashes once.
Release, then immediately
press and release again.
Reset LED flashes twice.
Press and hold
the Reset button.
Press and hold
the Reset button.
Reset LED flashes
three times.
Front panel I/O buttons flash twice.
Front panel I/O buttons flash three times.
Figure 61. Soft Resets
2. Release the Reset button and then immediately press and release the Reset button
again. Nothing happens if the second momentary press does not occur within
1 second.