Extron electronic dip hdmi Network Router User Manual


 
DXP DVI Pro and DXP HDMI Series • SIS Configuration and Control 61
Command
ASCII Command
(Host to Switcher)
Response
(Switcher to Host)
Additional Description
Names
Write global preset name
EX&
,
X1#
NG
}
Nmg
X&
,
X1#]
Assign global preset
X&
the
name
X1#
.
Example:
E
1,Security 1NG
}
Nmg01,Security 1
]
Name global preset 1
Security 1.
Read global preset name
EX&
NG
} X1#]
View the name assigned to
global preset number
X&
.
Example:
E
2NG
}
Security 2
]
Write room name
EX^
,
X1#
NR
}
Nmr
X^
,
X1#]
Assign room preset
X^
the
name
X1#
.
Example:
E
1,Classrm 1NR
}
Nmr01,Classrm 1
]
Name room 1 Classrm 1.
Read room name
EX^
NR
} X1#]
Write room preset name
EX^
*
X*
,
X1#
NP
}
Nmp
X^
*
X*
,
X1#]
Example:
E
1*3,Podium_DVDNP
}
Nmp01*3,Podium_DVD
]
Name room 1, preset 3
Podium_DVD.
Read room preset name
EX^
,
X*
NP
}
X1#]
NOTES: Do not use leading spaces in preset names.
If a preset is unassigned,
X1#
is [unassigned].
If a global preset is saved, but not yet named, the default name is Preset
X&
.
If a room preset is saved, but not yet named, the default name is Rm
X^
Prst
X*
.
Write input name
EX!
,
X1#
NI
}
Nmi
X!
,
X1#]
Assign name
X1#
to Input
X!
.
Example:
E
1,Podium camNI
}
Nmi1,Podium cam
]
Name Input 1 Podium cam.
Read input name
EX!
NI
} X1#]
View the name of Input
X!
.
Write output name
EX#
,
X1#
NO
}
Nmo
X#
,
X1#]
Assign name
X1#
to
Output
X#
.
Example:
E
1,Main PJ1NO
}
Nmo1,Main PJ1
]
Name Output 1 Main PJ1.
Read output name
EX#
NO
} X1#]
View the name of Output
X#
.
Lock (Executive) Modes
NOTE: See “Locking and Unlocking the Front Panel (Executive Modes)” on page 37 for more information on the
lock modes.
Lock all front panel functions
1X
Exe1
]
Enable lock mode 1.
Lock advanced front panel
functions
2X
Exe2
]
Enable lock mode 2.
Unlock all front panel
functions
0X
Exe0
]
Enable lock mode 0.
View lock status
X
X$]
NOTE:
X!
= Input number 1 – maximum number of inputs for your model
X#
= Output number 1 – maximum number of outputs for your model
X$
= Current front panel lock mode 0 = unlocked, 1 = all front panel functions locked,
2 = basic functions unlocked
X^
= Room number (for room presets) Each room can have up to 10 room presets (
X*
) assigned.
X&
= Global preset number 0032. 00 = current configuration
X*
= Room preset number 00 – current ties for the room in view mode, 10 maximum
X1#
= Name Name of preset, room, input, or output
12 characters maximum for input, output, and global preset names
11 characters maximum for room names
Upper- and lowercase alphanumeric characters are valid.