Extron electronic MLS 608 D Switch User Manual


 
MLS 608 D Analog Signal Transmission Distance Table for Inputs and Outputs, in Feet and (Meters)
NOTE: The maximum transmission distances are determined by the frequency and resolution of the video signal being
routed. The table below species the recommended maximum distances when using Extron Enhanced Skew
Free AV UTP cable or UTP CAT 5, 5e, or CAT 6 cable, terminated with RJ-45 connectors.
The minimum TP cable length should be 25 feet from the MTP Tx to input 4.
It is possible to exceed the recommended distances; however, image quality may be reduced.
Video Format
MLS Pre-Peak Maximum Distance
Off On
High Quality Variable Quality
MLS Input MLS Output MLS Input MLS Output
Component,
S-video
<300 (90) >350 (105) 700 (215) 700 (215) 700 (215) 800 (245)
Composite
<300 (90)
>350 (105) 700 (215) 700 (215) 750 (230) 750 (230)
640x480
<300 (90)
>350 (105) 550 (170) 600 (185) 600 (185) 650 (200)
800x600
<300 (90)
>350 (105)
500 (150) 500 (150) 600 (185) 600 (185)
1024x768*
<300 (90)
>350 (105)
450 (135) 450 (135) 550 (170) 550 (170)
1280x960*
<300 (90)
<350 (105)
350 (105) 350 (105) 450 (135) 450 (135)
1280x1024*
<250 (75) >300 (90) 350 (105) 350 (105) 450 (135) 450 (135)
1360x765
<250 (75) >300 (90) 350 (105) 350 (105) 500 (150) 500 (150)
1365x768
<250 (75) >300 (90) 350 (105) 350 (105) 450 (135) 450 (135)
1366x768
<250 (75) >300 (90) 350 (105) 350 (105) 450 (135) 450 (135)
1440x900
<250 (75) >300 (90) 350 (105) 300 (90) 400 (120) 400 (120)
1400x1050
<250 (75) >300 (90) 350 (105) 300 (90) 400 (120) 400 (120)
1600x1200
<250 (75) >300 (90) 300 (90) 300 (90) 450 (135) 450 (135)
1920x1200
<200 (60) >250 (75) 300 (90) 250 (75) 400 (120) 400 (120)
HDTV 720p
<250 (75) >300 (90) 400 (120) 400 (120) 500 (150) 500 (150)
HDTV 1080i
<200 (60) >250 (75) 300 (90) 250 (75) 400 (120) 400 (120)
HDTV 1080p
<200 (60) >250 (75) 300 (90) 250 (75) 400 (120) 400 (120)
Figure 4. Transmission Distance Table for Analog Signals
e Optional MTP power output — This port is for use with an MTP/HDMI U R receiver,
and is rated at 12 VDC with a current draw of 1 A, 12 watts.
This supplies sufficient power via the MLS device to fully power the MTP unit.
NOTE: When the power save mode is set to on, this port also turns off.
Captive Screw
Connector
Tie Wrap
3
5
Figure 5. Wiring the MLS 608 D Power Output Connector
MLS 608 D Series • Rear Panel Connections 10