Audio — from MTP input — MTP/HDMI U R
Gain ............................................... Unbalanced output: 0dB; balanced output +6 dB
Frequency response ........................ 20 Hz to 20 kHz, ±1 dB
THD + Noise ................................... 0.15% @ 1 kHz, 0.3% @ 20 kHz at nominal level
S/N ................................................. >70 dB at maximum output (unweighted)
Audio input — from MTP input, MTP/HDMI U R — see MLS 608 D's
audio output specications
Number/signal type ........................ 1 set of proprietary analog signals
Connectors .................................... 1 female RJ-45
NOTE: 0 dBu = 0.775 Vrms, 0 dBV = 1 Vrms, 0 dBV 2 dBu.
Audio output — from MTP input — MTP/HDMI U R
Number/signal type ........................ 2 mono, balanced/unbalanced
Connectors .................................... (1) 3.5 mm captive screw connector, 5 pole
Impedance ..................................... 50 ohms unbalanced, 100 ohms balanced
Gain error ...................................... ±1 dB channel to channel
Control/remote — external device (pass-through) — from HDMI input — MTP/HDMI U R
Serial control port input/output ...... RS-232 via (1) 3.5 mm, 3 pole captive screw connector
NOTE: The serial communications link of a MTP/HDMI U R is bidirectional.
Serial control pin configuration ....... Captive screw connectors: 1 = Tx, 2 = Rx, 3 = GND
Control/remote — external device (pass-through, unidirectional or bidirectional)
from MTP input — MTP/HDMI U R
NOTE: This port is not used when the MTP/HDMI U R is used with an MLS 608 D Series switcher.
Serial control port input/output ...... RS-232 via (1) 3.5 mm, 5 pole captive screw connector (3 poles are used)
Baud rates ...................................... Up to 38400 bps at up to 600' (183 m) (Higher data rates and distances are possible.
Performance varies based on baud rate and cable length.)
Protocol ......................................... Data bits = 5 - 8
Stop bits = 1 or 2
Parity = odd, even, none
Flow control = XON, XOFF, none
NOTE: Protocol is mirrored between the transmitter and the receiver.
Serial control pin configuration ....... Captive screw connector: 1 = Tx, 2 = Rx, 3 = GND
MLS 608 D Series • Reference Material 90