Extron electronic MLS 608 D Switch User Manual


 
Use this volume adjustment knob to set or adjust the program output volume
(attenuation, from -100 dB to 0 dB) as desired. The LEDs indicate the overall
percentage level for Group Master 1; the volume level being all off (0%) at -100 dB
through to all on (100%) at -4 to 0 dB. Any level changes made do not affect the mic
audio.
Rotate the knob clockwise to increase volume,
counter-clockwise to decrease volume. The
corresponding LEDS light as the knob is rotated.
See the table at right for LED/dB values.
Volume control of Group 1 individual program
outputs (programs 1, 3, or 4) can be made
through DSP Congurator software. Group 1
can be reconfigured through DSP Configurator
software.
f Mic volume adjustment knob This knob
is assigned to Group Master 2, which controls
the mic inputs at the second gain block, pre-mic
mixer-gain programs (see figure 12). By default it controls both microphones, and
level changes do not affect the program audio.
Use this knob to set or adjust the two MIC volumes as desired from -100 dB to 0 dB.
The LEDs indicate the volume level. See the table at above right for LED/dB values.
Rotate the knob clockwise to increase volume, counter-clockwise to decrease volume.
The corresponding LEDS light as the knob is rotated.
Volume control of Group 2 individual mic levels (mic pre-mixer gains 1 and 2) can be
made through DSP Configurator software.
Group 2 can be recongured through DSP Congurator software.
NOTE: The program and mic volume settings and adjustments can also be made
using Extron DSP Congurator program or by Simple Instruction Set (SIS)
commands. See the “Using the DSP Configurator Software”section
and the “SIS Programming and Control” section for details.
Using EDIDs
EDID Minder
This pre-installed feature ensures that all sources power up properly and reliably
output content for display. EDIDs (resolution and refresh rates) for digital inputs can be
automatically assigned when connecting a display with a common resolution and refresh
rate. For both analog and digital, the user can assign a different EDID from an EDID table.
A different EDID (as given in the table on the next page), can be manually assigned using
SIS commands or via DSP Configurator.
For the MLS 608 D units, the default settings are 1024x768 at 60 Hz for analog inputs,
and 720p at 60 Hz, 2-channel PCM audio for digital inputs.
NOTES: To work with the EDID Minder, update the EDID table, and import or export
EDID data, the MLS 608 D must be connected in Live mode.
VOLUME
LED equivalent
dB value
-4 to 0
-9 to -5
-14 to -10
-19 to -15
-29 to -20
-49 to -30
- 69 to -50
-99.9 to -70
-100 (all LEDs
off)
MLS 608 D Series • Operation 22