Extron electronic MLS 608 D Switch User Manual


 
X4# = Executive mode (front panel lock): 0 = off (all unlocked, default), 1 = lockout all (input buttons
and encoders), 2 = lockout input buttons only
X4$ = Baud rate: 300, 600, 1200, 1800, 2400, 3600, 4800, 7200, 9600, 28800, 38400 (default),
57600, 115200
X4% = Parity, Odd, Even, None (default), Mark, Space, (only use first letter, for example N = None)
X4^ = Data bits: 7, 8 (default = 8)
X4& = Stop bits: 1, 2 (default = 1)
X4* = Verbose mode: 0 = no verbose mode and non-tagged responses for queries, 1 = verbose
mode and non-tagged responses for queries (default), 2 = no verbose and tagged responses
for queries, 3 = verbose mode and tagged responses for queries
X4( = Mute status: 0 = mute off, 1 = mute on (default)
X5) = Mute value: +00000 = off, +00001 = on (default)
X5! = Mic number: 40100 = Mic 1, 40101 = Mic 2
X5@ = Alpha numeric up to 24 characters. No special characters except hyphen (-). No lower/upper
case distinction, no blanks or spaces. First character must be alpha, last cannot be hyphen
X5# = Alpha numeric name. Combination of unit name and last three pairs of unique alpha-numeric
characters (for example MLS-608-D-MA-06-DE-2E.
MLS 608 D Series • SIS Programming and Control 67