Extron electronic MLS 608 D Switch User Manual


 
General — MTP/HDMI U R
Recommended cable type .............. Shielded (recommended) or unshielded
MTP input ................................ CAT 5/5e/6
HDMI digital input ................... CAT 5/5e/6, Extron STP201
NOTE: Shielded twisted pair cable provides added protection from outside interference and increases overall signal
transmission distance. Extron strongly recommends using shielded twisted pair for optimal performance.
Power supply .................................. External
Input: 100-240 VAC, 50-60 Hz
Output: 12 VDC, 1 A, 12 watts
Power consumption ....................... 9.8 watts
Temperature/humidity .................... Storage: -40 to +158°F (-40 to 70°C)/10% to 90%, noncondensing
Operating: +32 to +122°F (0 to +50°C)/10% to 90%, noncondensing
Cooling .......................................... Convention, no vents
Thermal dissipation ........................ 18.1 BTU/hr
Mounting
Rack mount ............................. Yes, with optional 1U rack shelf
Furniture mount ...................... Yes, with optional under-desk mounting kit
Pole mount .............................. Yes, with optional projector mounting kit
Enclosure type ................................ Metal
Enclosure dimensions ..................... 1.7" H x 8.75" W x 3.0" D (half rack wide)
(4.3 cm H x 22.2 cm W x 7.6 cm D)
(Depth excludes connectors.)
Product weight ............................... 0.8 lbs (0.4 kg)
Shipping weight ............................. 13 lbs (6 kg) including MLS 608 switcher
Vibration ........................................ ISTA 1A in carton (International Safe Transit Association)
Regulatory compliance
Safety ...................................... CE, c-UL, UL
UL rated for use in plenum airspaces: meets UL 2043 for heat and smoke release,
excluding the power supply.
EMI/EMC ................................. CE, C-tick, FCC Class A, ICES, VCCI
MTBF ............................................. 30,000 hours
Warranty ........................................ 3 years parts and labor
NOTE: All nominal levels are at ±10%.
NOTE: Specifications are subject to change without notice.
MLS 608 D Series • Reference Material 91