Extron electronic MLS 608 D Switch User Manual


 
Command ASCII Command
(host to switcher)
Response
(switcher to host)
Additional
Description
Set Group Master Value
Set value (dB)
EDX^*X*GRPM} GrpmDX^*X*]
Set the value X* for
group number X^.
NOTE: Reserved groups are: 1 = program volume, 2 = mic volume, 3 = output bass, 4 = output treble, 5 = output volume mute.
Audio mute or
unmute
EDX^*X%GRPM} GrpmDX^*X%]
Mute or unmute X% for
group number X^.
Increment value
EDX^*X&+GRPM} GrpmDX^*X&]
Increase the value by X&
for group number X^.
Decrement value
EDX^*X&-GRPM} GrpmDX^*X&]
Decrease the value by X&
for group number X^.
View master value
EDX^GRPM}
X*]
View group master value
X*.
Program Volume (Group Master 1)
Set value (dB)
ED1*X*GRPM}
GrpmD01*X*]
Set the value X* for
group master 1.
Example: ED1*0GRPM} GrpmD01*+00000]
Sets the value to 0 dB.
Example: ED1*-100GRPM} GrpmD01*-00100]
Sets the value to -10 dB.
Example: ED1*-1000GRPM} GrpmD01*-01000]
Sets the value to -100
dB.
Increment value
ED1*X&+GRPM}
GrpmD01*X*]
Increase the value X*
by X&.
Decrement value
ED1*X&-GRPM}
GrpmD01*X*]
Decrease the value X*
by X&.
View master value
ED1GRPM}
X*]
View current program
volume master value X*.
Mic Volume (Group Master 2)
Set value (dB)
ED2*X*GRPM}
GrpmD02*X*]
Set the value X* for
group master 2.
Example: ED2*0GRPM} GrpmD02*+00000]
Sets the value to 0 dB.
Example: ED2*-100GRPM} GrpmD02*-00100]
Sets the value to -10 dB.
Example: ED2*-1000GRPM} GrpmD02*-01000]
Sets the value to -100
dB.
Increment value
ED2*X&+GRPM}
GrpmD02*X*]
Increase the value X*
by X&.
Decrement value
ED2*X&-GRPM}
GrpmD02*X*]
Decrease the value X*
by X& .
View master value
ED2GRPM}
X*]
View master mic volume
value X*.
NOTE: X% = Audio mute: 0 = no mute, 1 = mute
X^ = Group master number: 1 through 32, groups 1 through 5 are reserved groups, see note above.
X& = Increment and decrement dB values: in 0.1 dB steps (multiply dB by 10, for example 10 = 1.0 dB).
X* = Master volume value: 0 to -100 dB, in 0.1 dB steps, For example 0 = 0 dB, -1 = -0.1 dB,
-10 = -1.0 dB, -100 = -10 dB, -1000 = -100 dB. See master volume table on page 64 for details.
X( = Group member OID number
MLS 608 D Series • SIS Programming and Control 70