FARGO electronic S000256 Printer User Manual


 
RESTRICTED USE ONLY FARGO Electronics, Inc.
Sensor Calibration
Calibrating the Color Ribbon Sensor
Symptom: There are problems with the color ribbon skipping panels or the incorrect colors
being applied to the card, requiring calibration of the Ribbon Sensor. Be certain to shade the
Printer from direct sources of light (e.g., the sun, florescent or incandescent lamps).
Steps Procedure
1 Remove the back cover of the Printer and locate the DIP switches on the Main
Circuit Board.
2 Set DIP switches 1, 2 and 3 to the ON position.
3 Align the color ribbon on the clear or yellow panel over the light-emitting portion
of the Ribbon Sensor.
4 Close both Top Cover of the Printer.
5 Run the self-test procedure. See the Performing the Standard Self Test
procedure on page 57.
6 After the Flipper Table rotates, two long beeps from the Printer will sound to
indicate that the Ribbon Sensor calibration is completed.
7 Remove the power plug from the Printer.
Continued on the next page
Fargo Electronics
PN # xxxxxx
Rev. X
Persona® C25 Card Printer User Guide (Rev. 4.0)
77