Extended Configuration Menu
Web-Based Management Interface
Intelligent Blade Panel Module
117
6.2.4.3 Managing Access Control (802.1x)
6.2.4.3.1 Defining Access Control Page
Configurable Data
Administrative Mode - This selector lists the two options for administrative mode: enable
and disable. The default value is disabled.
Command Buttons
Submit - Sends the updated screen to the IBP and causes the changes to take effect on
the IBP but these changes will not be retained across a power cycle unless a save is
performed.
6.2.4.3.2 Configuring each Port Access Control Configuration Page
Selection Criteria
Port - Selects the port to be configured. When the selection is changed, a screen refresh
will occur causing all fields to be updated for the newly selected port. All physical
interfaces are valid.
Configurable Data
Control Mode - This selector lists the options for control mode. The control mode is only
set if the link status of the port is link up. The options are:
force unauthorized: The authenticator port access entity (PAE) unconditionally sets the
controlled port to unauthorized
force authorized: The authenticator PAE unconditionally sets the controlled port to
authorized.
auto: The authenticator PAE sets the controlled port mode to reflect the outcome of the
authentication exchanges between the supplicant, authenticator, and the authentication
server.
Quiet Period - This input field allows the user to configure the quiet period for the selected
port. This command sets the value, in seconds, of the timer used by the authenticator state
machine on this port to define periods of time in which it will not attempt to acquire a
supplicant. The quiet period is the period for which the authenticator does not attempt to
acquire a supplicant after a failed authentication exchange with the supplicant. The quiet
period must be a number in the range of 0 and 65535. A quiet period value of 0 means that
the authenticator state machine will never acquire a supplicant. The default value is 60.
Changing the value will not change the configuration until the Submit button is pressed.
Transmit Period - This input field allows the user to configure the transmit period for the
selected port. The transmit period is the value, in seconds, of the timer used by the
authenticator state machine on the specified port to determine when to send an EAPOL