Fujitsu BX600 Server User Manual


 
Device Configuration Commands Command Reference
Intelligent Blade Panel Module
141
7.4.1.2 show interface
This command displays the Port monitoring information for the system.
Syntax
show interface <slot/port>
<slot/port> - is the desired interface number.
Default Setting
None
Command Mode
Privileged Exec
Display Message
Intf: The physical slot and physical port.
Type: If not blank, this field indicates that this port is a special type of port. The possible
values are:
PC Mbr - This port is a member of a port-channel (LAG).
Description: This description of a port.
Admin Mode: Selects the Port control administration state. The port must be enabled in
order for it to be allowed into the network. – It may be enabled or disabled. The factory
default is enabled.
Physical Mode: Selects the desired port speed and duplex mode. If auto-negotiation
support is selected, then the duplex mode and speed will be set from the auto-negotiation
process. Note that the port's maximum capability (full duplex -100M) will be advertised.
Otherwise, this object will determine the port's duplex mode and transmission rate. The
factory default is Auto.
Physical Status: Indicates the port speed and duplex mode.
Link Status: Indicates whether the Link is up or down.
Link Trap: This object determines whether to send a trap when link status changes. The
factory default is enabled.
Flow Mode: Displays flow control mode.
Capabilities Status: Displays interface capabilities.
7.4.1.3 show interface counters
This command displays a summary of statistics for a specific interface or all interfaces.
Syntax
show interface counters {<slot/port> | all}
<slot/port> - is the desired interface number.