7.5.2.4 exec-timeout
This command specifies the maximum connect time (in minutes) without console activity. A
value of 0 indicates that a console can be connected indefinitely. The time range is 0 to 160.
Syntax
exec-timeout <0-160>
<0-160> - max connect time (Range: 0 -160).
no -
This command sets the maximum connect time (in minutes) without console activity to
5.
Default Setting
5
Command Mode
Line Config
7.5.2.5 password-threshold
This command is used to set the password instruction threshold limiting the number of failed
login attempts.
Syntax
password-threshold <0-120>
no password-threshold
<threshold> - max threshold (Range: 0 - 120).
no -
This command sets the maximum value to the default.
Default Setting
3
Command Mode