Fujitsu BX600 Server User Manual


 
Device Configuration Commands Command Reference
Intelligent Blade Panel Module
162
Syntax
port-group <portGroupName>
no port-group <portGroupName>
<portGroupName> - A string associated with port group as a convenience. It should be
an existing port group.
no - This command remove a port from a port group.
Default Setting
None
Command Mode
Interface Config
7.4.7 Port Backup
7.4.7.1 Show Commands
This command display the port backup information.
Syntax
show port-backup [ <uplinkSetName> [status] | status ]
<uplinkSetName> - The name of a uplink set which user want to display.
Default Setting
None
Command Mode
Privileged Exec
Display Message
Uplink Set Name: This indicates the name of uplink set.
Port Backup:. This indicates port-backup is enabled or disabled.
External Active Ports: This indicates which ports are in active-port list.
External Backup Ports: This indicates which ports are in backup-port list.