Fujitsu C141-E090-02EN Computer Drive User Manual


 
C141-E090-01EN 5 - 45
(24) STANDBY (X'96' or X'E2')
Upon receipt of this command, the device sets the BSY bit of the Status register and enters the
standby mode. The device then clears the BSY bit and generates an interrupt. The device
generates an interrupt even if the device has not fully entered the standby mode. If the device
has already spun down, the spin-down sequence is not implemented.
If the contents of the Sector Count register is other than 0, the automatic power-down function
is enabled and the timer starts countdown when the device returns to idle mode.
When the timer value reaches 0 (passed a specified time), the device enters the standby mode.
If the contents of the Sector Count register is 0, the automatic power-down function is
disabled.
Under the standby mode, the spindle motor is stopped. Thus, when the command involving a
seek such as the READ SECTOR(s) command is received, the device processes the command
after driving the spindle motor.
At command issuance (I/O registers setting contents)
1F7
H
(CM) X'96' or X'E2'
1F6
H
(DH)
× × ×
DV xx
1F5
H
(CH)
1F4
H
(CL)
1F3
H
(SN)
1F2
H
(SC)
1F1
H
(FR)
xx
xx
xx
Period of timer
xx
At command completion (I/O registers contents to be read)
1F7
H
(ST) Status information
1F6
H
(DH)
× × ×
DV xx
1F5
H
(CH)
1F4
H
(CL)
1F3
H
(SN)
1F2
H
(SC)
1F1
H
(ER)
xx
xx
xx
xx
Error information
(25) STANDBY IMMEDIATE (X'94' or X'E0')
Upon receipt of this command, the device sets the BSY bit of the Status register and enters the
standby mode. The device then clears the BSY bit and generates an interrupt. This command
does not support the automatic power-down sequence.