Fujitsu C141-E090-02EN Computer Drive User Manual


 
C141-E090-01EN3 - 8
3.3.2 Cable connector specifications
Table 3.2 lists the recommended specifications for the cable connectors for Host system that
do not support Ultra DMA modes greater than mode 2.
For Host system that support Ultra DMA modes greater than mode 2, it is recommended to
use the 80-conductor cable assembly. The 80-conductor cable assembly is manufactured by
AMP or 3M.
Table 3.2 Cable connector specifications
Name Model Manufacturer
Cable socket
(closed-end type)
FCN-707B040-AU/B Fujitsu
Cable socket
(through-end type)
FCN-707B040-AU/O Fujitsu
Cable socket housing 1-480424-0 AMP
Contact 60617-4 AMP
Note :
The cable of twisted pairs and neighboring line separated individually is not allowed to use
for the host interface cable. It is because that the location of signal lines in these cables is
not fixed, and so the problem on the crosstalk among signal lines may occur.
It is recommended to use the ribbon cable for ATA interface that cable length is less than
18 inch (46 cm) and cable capacitance is less than 35 pico farad. Also it is recommended
to use AWG18 power supply cable.
3.3.3 Device connection
Figure 3.8 shows how to connect the devices.
ATA interface cable
Power supply cable
DC
power supply
Disk Drive #1
Disk Drive #0
Host system
Figure 3.8 Cable connections
Power supply cable
(CN1)
ATA interface cable
(40-pin, CN1)