12 System Features
JP6: Termination jumper enables or disables termination for the backplane.
The backplane is designed to occupy one end of the bus and is usually
terminated. If you configure the SCSI bus so the backplane is not at the end
of the bus, disable termination. Set the jumper according to the table below.
SCSI connector provides the point of connection for the SCSI cable from the
RAID controller.
Power connector provides the point of connection for the power cable from
the power supply.
Reserved LED (6) reserved for future use.
Drive activity LED (6) glows green when the drive is actively reading or
writing data.
SCA SCSI drive connector (6) provides the single point of connection for
the six SCA SCSI drives.
Position Description
On Termination is disabled
Off (default) Termination is enabled
Drive activity LED (6)Reserved LED (6)
SCA SCSI drive connector (6)
Front of the hot-plug backplane board
SCSI ID 0
SCSI ID 1
SCSI ID 2
SCSI ID 3
SCSI ID 4
SCSI ID 5
8505945.book Page 12 Thursday, March 9, 2000 2:13 PM